Command: drum stop


Description:

Stops the drum in less than one rotation and idles the drum if the h option is not specified. The drum servo actively brakes the drum.

[h]

Applies a holding torque.

[p]

Brakes the drum passively, i.e., the drum is slowed simply by connecting a resistor across the drum motor windings. At normal imaging speeds, the drum may take as long as 3 seconds to stop. The drum is idled once it has come to a complete stop.


Applies To:

  • All

Syntax:

drum stop [h] [p]


Notes:


See Also:


Go to CTP Firmware Commands Index Page

Go to CTP Firmware Main Page


Creo CTP F/W Command Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:05:00 2002 PST