Command: dvac


Description:

View the status of, or perform general commands on the drum vacuum. The following command options are possible:

dvac - Displays the drum vacuum on/off status and the measured vacuum level.

dvac on - Turns on the drum vacuum.

dvac off - Turns off the drum vacuum.

dvac generator on - Turns on the vacuum generator

dvac generator off - Turns off the vacuum generator

dvac counter - Displays the drum vacuum life timer

dvac counter reset - Resets the drum vacuum life timer


Applies To:

  • Trendsetter_400/800_Proofing

Syntax:

dvac [on|off|generator (on|off)|counter (reset)]


Notes:


See Also:


Go to CTP Firmware Commands Index Page

Go to CTP Firmware Main Page


Creo CTP F/W Command Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:05:00 2002 PST