Command: list stats


Description:

Machine statistics.

  1. On time - total time recorder has been powered up ("set state general ttime")
  2. Time busy - total time images have been active, including suspended ("set state general btime")
  3. Time suspended - total time recorder has been suspended ("set state general stime")
  4. Door opened 2 times for a total time of 0:05:31 - ("set state general door" and "set state general dtime")
  5. Power up or operator reset - "normal" startups ("set state general pcnt")
  6. Fault reset - recorder resets due to software crash, mixing monitor and workstation commands, etc. This count also includes resets from the boot monitor, i.e. when loading new firmware ("set state general fcnt")
  7. Min temperature - minimum engine temperature measured ("set state general tmin")
  8. Max temperature - maximum engine temperature measured ("set state general tmax")
  9. Low pressure time - total time recorder low air pressure condition has been detected ("set state general ptime")
  10. Total images - total workstation images started ("set state general ti")
  11. Total failed - total workstation images failed due to a recorder error. Note that while an image is in progress, it is counted as "failed". ("set state general fi")
  12. Total cancelled - total workstation images cancelled by operator or RIP error ("set state general ci")
  13. Total imaging retraces - total number of times the recorder has had to wait for the RIP to catch up. This stat is updated only at the end of each image ("set state imaging ret")
  14. Failed edge detects - number of times edge detection failed after a full set of attempts ("set state imaging fail")
  15. False edges - number of times a false edge was detected ("set state imaging false")

  1. Most recent stroke calibrations (stroke init 2048) - the stray light and the minimum and maximum power levels for two different modes are recorded at the time of the last stroke calibration. The two modes are chosen with the "set sys s1" and "set sys s2" parameters and default to modes 1 & 2. Note that the stroke is initialized to 2048 (half power) for the max and min measurements.
  2. Mode - measurements were made in this mode ("set sys s1" and "set sys s2")
  3. Stray light - measured with no power to Data AOM ("set state head stray1")
  4. Min power - power of minimum pixels at Data AOM settng of 2048 ("set state head min1")
  5. Max power - power of maximum pixels at Data AOM settng of 2048 ("set state head max1")

  1. Laser re-calibration count - number of spontaneous laser calibrations, not including those caused by power-ups or resets ("set state laser rc")
  2. The last laser calibration occured at 0:52:51 and took 362 seconds - time of most recent laser calibration, relative to "on time", and the duration ("set state laser tc", "set state laser cl")
  3. Total DAOM illumination time - total time that the Data AOM shutter has been open. This timer is updated even if the DAOM shutter is not installed. ("set state head dtime")
  4. Total DAOM shutter cycles - number of times the DAOM shutter is opened. Updated even if shutter is not installed. ("set state head dso")

  1. Total drum vacuum pump on time ("set state general dvtime") (Proofing only)
  2. Proofing media usage (Proofing only)


Applies To:

  • All

Syntax:

list stats


Notes:

The stats values are stored in NVS and should not be affected by an nvs upgrade command unless there is a change to the stats system as part of the new firmware, old data will normally not be lost.

To initialize ALL statistics, including "on time" type: "nvs init stats" DO NOT DO THIS

To initialize all counters in one subsystem type: "nvs init stats <subsys> [index]"

e.g. "nvs init stats laser"

To reset an individual counter type: "set state <subsys> <name> 0"

e.g. "set state mstats 1 pif 0"


See Also:


Go to CTP Firmware Commands Index Page

Go to CTP Firmware Main Page


Creo CTP F/W Command Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:05:02 2002 PST