Command: stroke init


Description:

Initializes the stroke DAC values to a constant value. If <value> is specified, it must be an integer in the range 0 to 4095. If <value> is not given, it defaults to 2047 (half the maximum).

If the <slope> is given, it specifies a tilted profile instead of a constant one. This slope is the change in DAC value per pixel (NOT per sample). The <slope> is a signed integer (i.e. slope can be positive or negative). If a slope is given which causes the pixel's amplitude to reach 0 or 4095, the slope changes sign at this pixel. The resulting pattern will look something like a sawtooth.


Applies To:

  • Green

Syntax:

stroke init [<value> [<slope>]]


Notes:


See Also:


Go to CTP Firmware Commands Index Page