Description: |
This is an easy way of reading the unload vacuum and/or turning it on or off. "uvac" on it's own returns the current unload table vacuum reading. "uvac on" turns the vacuum on immediately, "uvac off 5" waits 5 seconds then turns the vacuum off then retracts the unload cups. This is useful for removing a plate from the unload table nicely. "uvac grab 7" extends the unload cups immediately and turns on the unload vacuum 7 seconds later, which gives you time to position the plate. |
Applies To: |
|
Syntax: |
uvac on|off|grab <delay> |
Notes: |
See Also: |
Go to CTP Firmware Commands Index Page