NVS Parameter: al aso


Long Name:

air_supply_offset

Applies to:

  • ThermoFlex

  • Description:

    The air_supply_offset parameter is used to calibrate the system pressure. This parameter increases the threshold for system pressure set in the sys category of nvs. If the system pressure should fall below the threshold plus the offset then an alert will be triggered and the machine will not function until the system pressure is restored to a suitable level


    Type:

    int8

    Default:

    • 0

    Range:

    • 0 to 25 (psi)

    Notes:


    Partition:

    cal

    See Also:

  • parameter sys_pressure_thresh

  • Go to CTP Firmware NVS Parameter Index Page

    Go to CTP Firmware NVS Parameter Search Page

    Go to CTP Firmware Main Page


    Creo CTP F/W NVS Parameter Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:03:09 2002 PST