NVS Parameter: al aso


Long Name:

air_supply_offset

Applies to:

  • Platesetter_VLF
  • Trendsetter_VLF

  • Description:

    compensates for a DC offset in the system air pressure sensor. This can be set by using the 'cal pressure' command so that the pressure sensor is calibrated to 0 psi when there is no air pressure to the system.


    Type:

    signed integer

    Default:

    • 0

    Range:

    • -80 to 80 [psi]

    Notes:


    Partition:

    cal

    See Also:


    Go to CTP Firmware NVS Parameter Index Page

    Go to CTP Firmware NVS Parameter Search Page

    Go to CTP Firmware Main Page


    Creo CTP F/W NVS Parameter Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:03:09 2002 PST