NVS Parameter: al bte


Long Name:

bad_te_sensor

Applies to:

  • Platesetter_3244

  • Description:

    Modifies main TEC backbone cylinder sensing algorithim.

    For TEC lower commands, the firmware normally waits for TEC_LOWERED cylinder sensor to be true And the TEC_RAISED cylinder sensor to be false. Reverse applies to TEC raise commands.

    If bte=1 (implies one or other sensor is bad) then only TEC_LOWERED sensor is checked when the TEC is lowered and only TEC_RAISED is checked if TEC is raised. IF the TEC doesn't arrive at it's destination within time (see aldly te_delay) then a timeout error is generated. If destination sensor is disabled (see al no_le_sensor / al no_te_sensor) then defaults to same time delay of (aldly te_delay) and no error is generated provided bte is also set.

    BTE also applies to TEC LOCK. TEC LOCK works the same way except it only applies to the locking direction, if bte =1 it only checks the lock sensor when locking and the unlock sensor when unlocking, if bte=0 then it checks the lock and unlock sensor when it is moving in the Locking direction.


    Type:

    integer

    Default:

    • 0

    Range:

    • 0 to 1

    Notes:


    Partition:

    cal

    See Also:

  • NVS: al nte
  • NVS: al nle
  • NVS: aldly te
  • Other: Platesetter Acronyms and Definitions

  • Go to CTP Firmware NVS Parameter Index Page

    Go to CTP Firmware NVS Parameter Search Page

    Go to CTP Firmware Main Page


    Creo CTP F/W NVS Parameter Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:03:09 2002 PST