NVS Parameter: al hsap


Long Name:

hstage_away_pos

Applies to:

  • ThermoFlex

  • Description:

    The head stage is used to focus the head (roughly) on the very varied thicknesses of flexo media, it is also used to measure the thickness of each plate as it is loaded so that distortion calculations can be done correctly. When installed, the hstage moves to the away position and at that time this paramter is automatically updated. From that point on, this position corresponds to the drum surface, and by knowing where the head stage is after it zero's on a piece of media, the media thickness in steps can be calculated.

    Changing this value without re-zeroing the head on the drum (using "stage install") will affect measured media thicknesses and therefore image size.


    Type:

    uint16

    Default:

    • 0

    Range:

    • 0 to 5000 [steps]

    Notes:


    Partition:

    cal

    See Also:


    Go to CTP Firmware NVS Parameter Index Page

    Go to CTP Firmware NVS Parameter Search Page

    Go to CTP Firmware Main Page


    Creo CTP F/W NVS Parameter Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:03:09 2002 PST