Long Name: | lec_drum_pos |
Applies to: |
|
Description: |
This is the drum position at which the leading-edge (LE) actuator is lined up with the LE clamps. Whenever the clamps are automatically opened, this is the position the drum is first moved to. |
Type: | int32 |
Default: |
|
Range: |
|
Notes: |
The way the LE clamps are hinged will make the drum slightly move when you open them. Therefore, when setting this parameter do not use the drum position after the clamps are opened, but rather the postion that lines up the LE actuator with the LE clamps before they are opened. |
Partition: | cal |
See Also: |
Go to CTP Firmware NVS Parameter Index Page