NVS Parameter: al lr


Long Name:

load_ramp_sensor

Applies to:

  • Trendsetter_400/800
  • Trendsetter_400/800_Proofing

  • Description:

    Enables or disables checking of the load ramp position sensor.

    • lr = 1 enables checking of sensor.
    • lr = 0 disables checking of sensor.


    Type:

    integer

    Default:

    • 0

    Range:

    • 0 to 1

    Notes:

    Disabling this sensor is dangerous as the load ramp could be in the no-fly zone of the drum and the firmware will not check it, before attempting to spin the drum.


    Partition:

    cal

    See Also:


    Go to CTP Firmware NVS Parameter Index Page

    Go to CTP Firmware NVS Parameter Search Page

    Go to CTP Firmware Main Page


    Creo CTP F/W NVS Parameter Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:03:10 2002 PST