NVS Parameter: al ms


Long Name:

mag_sensor

Applies to:

  • Trendsetter_400/800_Auto
  • Trendsetter_NEWS

  • Description:

    When set (1), this flag enables checking of the sensors which determine if the Trailing Edge (TE) clamps are on the actuator. When cleared, (0), the sensor is by-passed and the state al te flag is used to keep track of where the TE clamps are.


    Type:

    byte

    Default:

    • 1

    Range:

    • 0 to 1

    Notes:

    If this flag is cleared, (0), machine operation is significantly slowed down and some critical safety checks are not done. Clearing this flag should only be done on a temporary basis and the sensor should be repaired as soon as possible. Please do not clear this flag unless absolutely necessary!

    This flag was previously named "nms" in other products.


    Partition:

    cal

    See Also:

  • Command: engine

  • Go to CTP Firmware NVS Parameter Index Page

    Go to CTP Firmware NVS Parameter Search Page

    Go to CTP Firmware Main Page


    Creo CTP F/W NVS Parameter Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:03:10 2002 PST