NVS Parameter: al nds


Long Name:

no_drawer_sensor

Applies to:

  • Platesetter_3244

  • Description:

    Disables checking of drawer closed sensor.

    • nds = 0 enables checking of sensor.
    • nds = 1 disables checking of sensor.


    Type:

    integer

    Default:

    • 0

    Range:

    • 0 to 1

    Notes:

    Debounces for time (sensor_delay) milliseconds (if nds=0), else delays for (load_drawer) seconds (default 10 minutes) and assumes drawer is closed.


    Partition:

    cal

    See Also:

  • NVS: aldly sensor
  • NVS: altim cb_load
  • Other: Platesetter Acronyms and Definitions

  • Go to CTP Firmware NVS Parameter Index Page

    Go to CTP Firmware NVS Parameter Search Page

    Go to CTP Firmware Main Page


    Creo CTP F/W NVS Parameter Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:03:10 2002 PST