NVS Parameter: al nlps


Long Name:

no_load_plate_sensor

Applies to:

  • Trendsetter_400/800

  • Description:

    Disables checking of the optical load ramp plate sensor during loads.

    • nlps=1 disables checking of the sensor.
    • nlps=0 enables checking of the sensor.

    On Trendsetter_400/800 the optical sensor is used to measure the plate as it is wound onto the drum. If this sensor is disabled, no checking is done and it is assumed that the operator has loaded the correct size plate.


    Type:

    integer

    Default:

    • 0

    Range:

    • 0 to 1

    Notes:


    Partition:

    cal

    See Also:

  • Other: Platesetter Acronyms and Definitions

  • Go to CTP Firmware NVS Parameter Index Page

    Go to CTP Firmware NVS Parameter Search Page

    Go to CTP Firmware Main Page


    Creo CTP F/W NVS Parameter Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:03:10 2002 PST