NVS Parameter: al nss


Long Name:

no_shutter_sensor

Applies to:

  • Platesetter_3244

  • Description:

    Disables the checking of the shutter cylinder sensors.

    • nss = 0 enables checking of sensor.
    • nss = 1 disables checking of sensor.


    Type:

    integer

    Default:

    • 0

    Range:

    • 0 to 1

    Notes:

    When the sensors are disabled (nss=1) then the firmware defaults to delay of (shutter_delay) milliseconds before it assumes the cylinder moved as directed. When enabled (nss=0) the same amount of time is allowed for the appropriate sensor to be detected before a timeout error is generated.


    Partition:

    cal

    See Also:

  • NVS: aldly shut
  • Other: Platesetter Acronyms and Definitions

  • Go to CTP Firmware NVS Parameter Index Page

    Go to CTP Firmware NVS Parameter Search Page

    Go to CTP Firmware Main Page


    Creo CTP F/W NVS Parameter Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:03:10 2002 PST