Long Name: | no_table_sensor |
Applies to: |
|
Description: |
Disables the checking of the sensors on the Table_Tilt_Cylinder. The sensors indicate cylinder extended and cylinder retracted. When nts=1 then the firmware will not check the position of the cylinder after causing it to move.
Disables the checking of the sensors on the Table_Stow_Cylinder. The sensors indicate cylinder extended and cylinder retracted. When nts=1 then the firmware will not check the position of the cylinder after causing it to move.
|
Type: | integer |
Default: |
|
Range: |
|
Notes: |
Table_Tilt_Cylinder tilts the table for load and unload. Table_Stow_Cylinder together with Table_Tilt_Cylinder tilts the table to the eject position for feeding the plate into the conveyer. If sensor disabled (nts=1), Firmware defaults to using time delay instead of waiting for the cylinder extended (or retracted) sensor to become true. timer: in milliseconds set by SET ALDLY TTILT. When the sensor is enabled a timeout error if generated is the cylinder extended (or retracted) sensor does not become true with in a certain time. The same value is used for timeout when sensor is enabled. |
Partition: | cal |
See Also: |
|