NVS Parameter: al nups


Long Name:

no_unload_plate_sensor

Applies to:

  • Platesetter_3244

  • Description:

    Disables optical plate sensor on the unload table. There are two sensors on one board, the upper one is known as the unload_queued sensor and the lower one is known as the unloading_plate sensor. Both feed into the LUE board.

    • nups = 0 enables checking of both sensors.
    • nups = 1 disables checking of both sensors.


    Type:

    integer

    Default:

    • 0

    Range:

    • 0 to 1

    Notes:

    When unloading a plate from the drum, the firmware allows (sensor_delay) milliseconds for leading edge of the plate to get between sensors , that is unloading_plate covered and unload_queued not covered, if nups=0 (enabled). If nups=1 then no checking is done.


    Partition:

    cal

    See Also:

  • NVS: aldly sensor
  • Other: Platesetter Acronyms and Definitions