NVS Parameter: al pcs


Long Name:

plate_cover_sensor

Applies to:

  • Trendsetter_400/800_Auto
  • Trendsetter_NEWS

  • Description:

    When set, (1), this flag enables the sensor on the plate cover door on the load table. This sensor is used to verify that the door is close prior to picking a plate. When cleared, (0), the sensor is by-passed.


    Type:

    byte

    Default:

    • 1

    Range:

    • 0 to 1

    Notes:

    If this flag is cleared, (0), machine operation is significantly slowed down and some critical safety checks are not done. Clearing this flag should only be done on a temporary basis and the sensor should be repaired as soon as possible. Please do not clear this flag unless absolutely necessary!


    Partition:

    cal

    See Also:

  • Command: picker

  • Go to CTP Firmware NVS Parameter Index Page