NVS Parameter: al prs


Long Name:

pos_to_rotate_sensor

Applies to:

  • Trendsetter_400/800_Auto

  • Description:

    When set, (1), this flag enables the unload traveller rotate position sensor. This sensor is used to verify that the unload table traveller is in the correct (i.e. safe) location to rotate the plate. When cleared, (0), the sensor is by-passed and timeouts are used instead.


    Type:

    byte

    Default:

    • 1

    Range:

    • 0 to 1

    Notes:

    If this flag is cleared, (0), machine operation is significantly slowed down and some critical safety checks are not done. Clearing this flag should only be done on a temporary basis and the sensor should be repaired as soon as possible. Please do not clear this flag unless absolutely necessary!


    Partition:

    cal

    See Also:

  • Command: table
  • NVS: alpos crp

  • Go to CTP Firmware NVS Parameter Index Page

    Go to CTP Firmware NVS Parameter Search Page

    Go to CTP Firmware Main Page