NVS Parameter: al ucs


Long Name:

unload_cup_sensor

Applies to:

  • Trendsetter_400/800_Auto
  • Trendsetter_NEWS

  • Description:

    When set, (1), this flag enables the unload vacuum cup down sensor. This sensor is used to verify that the up/down actuator has successfully moved to the desired location. When cleared, (0), the sensor is by-passed and timeouts are used instead.


    Type:

    byte

    Default:

    • 1

    Range:

    • 0 to 1

    Notes:

    If this flag is cleared, (0), machine operation is significantly slowed down and some critical safety checks are not done. Clearing this flag should only be done on a temporary basis and the sensor should be repaired as soon as possible. Please do not clear this flag unless absolutely necessary!


    Partition:

    cal

    See Also:

  • Command: table
  • NVS: aldly ucud

  • Go to CTP Firmware NVS Parameter Index Page