NVS Parameter: al jdv


Long Name:

jog_drum_vel

Applies to:

  • ThermoFlex

  • Description:

    During the unload, the operator must hold up the trailing media edge while the drum jogs the plate back towards the table. This parameter sets how fast the drum moves while the operator is holding the plate. Once again, this parameter is set in milli-rpm


    Type:

    int32

    Default:

    • -5000L

    Range:

    • -40000L to 0L [mrpm]

    Partition:

    cfg

    See Also:


    Go to CTP Firmware NVS Parameter Index Page

    Go to CTP Firmware NVS Parameter Search Page

    Go to CTP Firmware Main Page


    Creo CTP F/W NVS Parameter Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:03:13 2002 PST