NVS Parameter: al ppsc


Long Name:

picker_press_sensor_cal

Applies to:

  • Trendsetter_VLF_Auto

  • Description:

    The stock pressure sensors are not accurate enough so this correction factor is set up during "cal pressure sensor" command.

    This nvs pertains to the picker pressure sensor (also measuring main line systrem pressure) mounted on the picker and attached to the picker genine.

    The value is access code protected and should not be changed by any means other than cal pressure sensor. 0 denote no correction i.e. a perfect sensor (not likely, more likely it's an uncalibrated sensor.


    Type:

    int16

    Default:

    • 1

    Range:

    • -32767 to 32767

    Notes:


    Partition:

    cfg

    See Also:

  • NVS: al mpsc
  • NVS: al aoff
  • Command: cal pressure

  • Go to CTP Firmware NVS Parameter Index Page

    Go to CTP Firmware NVS Parameter Search Page

    Go to CTP Firmware Main Page


    Creo CTP F/W NVS Parameter Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:03:14 2002 PST