NVS Parameter: al vpi


Long Name:

ver3_pkr_installed

Applies to:

  • Trendsetter_400/800_Auto

  • Description:

    The version 3 picker introduced on ECO #889 (#17 on the 100 label) must be enabled in firmware by setting this parameter to 1. Setting this parameter to 0 will enable the older version 2 picker.


    Type:

    byte

    Default:

    • 0

    Range:

    • 0 to 1

    Notes:

    Only supported in firmware versions 1.20 and above.


    Partition:

    cfg

    See Also:

  • Command: pick
  • Command: load
  • Command: picker
  • NVS: aldly phid
  • NVS: aldly pwod

  • Go to CTP Firmware NVS Parameter Index Page

    Go to CTP Firmware NVS Parameter Search Page

    Go to CTP Firmware Main Page


    Creo CTP F/W NVS Parameter Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:03:16 2002 PST