NVS Parameter: state al mdv


Long Name:

monitor_drum_vacuum

Applies to:

  • ThermoFlex

  • Description:

    This parameter determines whether the pressure level of the drum vacuum is checked against the threshold set in media dvt. When this parameter is set to 1 (done at the end of a load sequence) then the vacuum pressure is sensed and compared on a continuous basis. When set to zero this monitoring is disabled.

    This value is set back to zero during the unload sequence before the drum vacuum itself is turned off.


    Type:

    uint8

    Default:

    • 0

    Range:

    • 0 to 1

    Partition:

    state

    See Also:


    Go to CTP Firmware NVS Parameter Index Page