NVS Parameter: aldrv fr


Long Name:

fast_end_vel

Applies to:

  • ThermoFlex

  • Description:

    The fast_end_vel parameter is used to set the final target velocity for the head stage stepper motor when it is running at FAST speed. The motor ramps up from fast_start_vel to fast_end_vel at a rate specified by fast_accel and ramps back down using the same acceleration slope as it reaches its target position. If the value in fast_start_vel is larger than the value in fast_end_vel, then the stepper motor will start at the speed specified by the fast_end_vel and will not ramp up or down.

    FAST speed is only used if specified in a moveto diagnostic command

    The units used by this parameter are somewhat arbitrary. To convert them to actual steps per second, please consult the tables in the CY-545 data book.


    Type:

    byte

    Default:

    • 17

    Range:

    • 0 to 254

    ArraySize:

    2

    Partition:

    cfg

    See Also:

  • Command: stage
  • NVS: aldrv ff
  • NVS: aldrv fs

  • Go to CTP Firmware NVS Parameter Index Page

    Go to CTP Firmware NVS Parameter Search Page

    Go to CTP Firmware Main Page


    Creo CTP F/W NVS Parameter Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:03:20 2002 PST