NVS Parameter: aldrv mf


Long Name:

med_f

Applies to:

  • Platesetter_3244
  • Trendsetter_400/800_Proofing

  • Description:

    Sets the (F)irst stepping rate for moving the stepper motor at the medium speed. This is the initial rate immediately used to move the stepper at the beginning of any acceleration.


    Type:

    integer

    Default:

    • 0 (8 for Trendsetter_400/800_Proofing version 1.1 and above)

    Range:

    • 0 to 254

    Notes:

    The units used by this parameter are somewhat arbitrary. To convert them to actual steps per second, please consult the tables in the CY-545 data book.

    Syntax:

    • "set aldrv 1 mf <value>" where 1 is for PY
    • "set aldrv 2 mf <value>" where 2 is for PZ


    Partition:

    cfg

    See Also:


    Go to CTP Firmware NVS Parameter Index Page

    Go to CTP Firmware NVS Parameter Search Page

    Go to CTP Firmware Main Page


    Creo CTP F/W NVS Parameter Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:03:20 2002 PST