NVS Parameter: aldrv sds


Long Name:

step_direction_sense

Applies to:

  • Trendsetter_400/800_Auto
  • Trendsetter_NEWS

  • Description:

    The step_direction_sense parameter is used to control the active logic level for the stepper driver direction signal. The correct value for this parameter (0 or 1) will depend on the configuration and wiring of the stepper motor drive amplifier and motor.

    Syntax: set aldrv 2 sds

    Other products have more than one stepper motors axis, so used "set aldrv 1" and "set aldrv 2" for the separate axes. The 3244 Trendsetter Autoloader has only one axis, but kept the same parameter structure for consistency.


    Type:

    byte

    Default:

    • 0

    Range:

    • 0 to 254

    ArraySize:

    2

    Notes:


    Partition:

    cfg

    See Also:


    Go to CTP Firmware NVS Parameter Index Page

    Go to CTP Firmware NVS Parameter Search Page

    Go to CTP Firmware Main Page


    Creo CTP F/W NVS Parameter Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:03:21 2002 PST