NVS Parameter: aldrv ses


Long Name:

step_enable_sense

Applies to:

  • ThermoFlex

  • Description:

    The step_enable_sense parameter is used to control the active logic level for the stepper driver enable signal. The correct value for this parameter (0 or 1) will depend on the configuration of the stepper motor drive amplifier.

    For stepper motor amplifiers that use an active LOW enable signal, set this parameter to 0.

    For stepper motor amplifiers that use an active HIGH enable signal, set this parameter to 0.


    Type:

    byte

    Default:

    • 0

    Range:

    • 0 to 254

    ArraySize:

    2

    Partition:

    cfg

    See Also:


    Go to CTP Firmware NVS Parameter Index Page

    Go to CTP Firmware NVS Parameter Search Page

    Go to CTP Firmware Main Page


    Creo CTP F/W NVS Parameter Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:03:21 2002 PST