NVS Parameter: aldrv spm


Long Name:

steps_per_mm

Applies to:

  • ThermoFlex

  • Description:

    The steps_per_mm parameter is used to calculate the number of steps to move the head stage stepper motor based on a target position specified in millimeters. The value in this parameter must specify the number of pulses that the CY-545 motor conroller needs to output in order to move the unload traveller exactly one millimeter.

    The steps_per_mm parameter assumes an implicit decimal point, i.e. a value of 10 means that it takes exactly 1.0 pulses to move the traveller 1 millimeter.


    Type:

    word

    Default:

    • 3150

    Range:

    • 10 to 65535

    ArraySize:

    2

    Partition:

    cfg

    See Also:


    Go to CTP Firmware NVS Parameter Index Page

    Go to CTP Firmware NVS Parameter Search Page

    Go to CTP Firmware Main Page