NVS Parameter: aldrv ss


Long Name:

slow_accel

Applies to:

  • ThermoFlex

  • Description:

    The slow_accel parameter is used to control motor acceleration slope when the head stage stepper motor when it is running at SLOW speed. The motor ramps up from slow_start_vel to slow_end_vel at a rate specified by slow_accel and ramps back down using the same acceleration slope as it reaches its target position. If the value in slow_start_vel is larger than the value in slow_end_vel, then the stepper motor will start and stop at the speed specified by the slow_end_vel and will not ramp up or down.

    Decreasing this value will reduce the motor acceleration.

    For small acceleration values, the motor can take a very large number of steps to go from the start velocity to the end velocity. If the distance that the motor needs to move is too short for it to reach the end velocity, then it will perform a partial acceleration to the highest velocity attainable under the current acceleration value before starting to ramp back down to stop at the target position.

    SLOW speed is used when zeroing the head for the currently loaded media. It is also the default speed for moveto commands.

    The units used by this parameter are somewhat arbitrary. To convert them to actual steps per second, please consult the tables in the CY-545 data book.


    Type:

    byte

    Default:

    • 250

    Range:

    • 0 to 254

    ArraySize:

    2

    Notes:


    Partition:

    cfg

    See Also:

  • Command: stage
  • NVS: aldrv sf
  • NVS: aldrv sr

  • Go to CTP Firmware NVS Parameter Index Page

    Go to CTP Firmware NVS Parameter Search Page

    Go to CTP Firmware Main Page


    Creo CTP F/W NVS Parameter Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:03:21 2002 PST