NVS Parameter: alpos clr


Long Name:

clear_load_ramp

Applies to:

  • Trendsetter_400/800_Auto
  • Trendsetter_NEWS

  • Description:

    This value specifies the distance to drag the plate up the unload table during an UNLOAD command so that the bottom of the plate clears the load ramp and the unload table can be lowered. This is an absolute distance in mm measured from the HOME position which will be the same for all plate sizes. Increasing this value will cause the plate to be dragged further up the table during the UNLOAD command.


    Type:

    uint32

    Default:

    • 300

    Range:

    • 0 to 1000 [mm]

    Notes:


    Partition:

    cal

    See Also:

  • Command: unload

  • Go to CTP Firmware NVS Parameter Index Page