NVS Parameter: alpos p1z


Long Name:

process_pos1_z

Applies to:

  • Platesetter_3244

  • Description:

    Once the plate has been placed into the LEC and clamp and the roller lowered, the picker Z is moved out of way, (if plate was really small, the next unload would make plate crash into picker). The position which it moves to is process_pos1_z When the table is tilted for the eject cycle, then the picker is again confirmed clear by moving to this position.


    Type:

    integer

    Default:

    • 400000

    Range:

    • 0 to 450000 [mm]

    Notes:

    The double check upon eject is done after the stow cylinder is extended but before the tilt cylinder is extended.


    Partition:

    cal

    See Also:


    Go to CTP Firmware NVS Parameter Index Page

    Go to CTP Firmware NVS Parameter Search Page

    Go to CTP Firmware Main Page


    Creo CTP F/W NVS Parameter Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:03:22 2002 PST