NVS Parameter: alproof rvgt


Long Name:

rvac_grab_thresh

Applies to:

  • Trendsetter_400/800_Proofing

  • Description:

    This is the roller vacuum level that indicates the vacuum is holding a sheet of media. The units are arbitrary, scaled so the highest level the vacuum system could generate is about 255 (think bytes).

    The level is checked after the roller has alledgedly grabbed something, and if it is below this threshold, an error message pops up and the machine suspends.

    Set this parameter to zero to bypass the checking of this threshsold.


    Type:

    int16

    Default:

    • 550

    Range:

    • 0 to 1023 (no units)

    Notes:


    Partition:

    cal

    See Also:


    Go to CTP Firmware NVS Parameter Index Page

    Go to CTP Firmware NVS Parameter Search Page

    Go to CTP Firmware Main Page


    Creo CTP F/W NVS Parameter Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:03:24 2002 PST