NVS Parameter: altim lec


Long Name:

le_clamp_timeout

Applies to:

  • Trendsetter_VLF
  • Trendsetter_VLF_Auto

  • Description:

    The time in seconds the firmware will wait for the leading edge clamp to move to position. If the LEC clamp sensor is disabled the firmware will assume that it has moved to position after this time is elapsed. The LEC is a swinging subassembly mounted on the Trailing Edge Clamp (TEC) backbone. When the LEC clamp is in position the TEC effectively becomes the LEC.


    Type:

    uint32

    Default:

    • 4.000 seconds

    Range:

    • 0 to 10.000 seconds

    Notes:

    This parameter is stored as an integer value of milliseconds. It is entered by the user in seconds and displayed to the user in seconds. The user may enter up to three digits after the (optional) decimal point.


    Partition:

    cfg

    See Also:

  • NVS: al lecs

  • Go to CTP Firmware NVS Parameter Index Page