NVS Parameter: altim pht


Long Name:

processor_handoff_timeout

Applies to:

  • Trendsetter_400/800_Auto
  • Trendsetter_NEWS

  • Description:

    The processor_handoff_timeout parameter specifies that maximum amount of time that the recorder will wait for a plate to leave the unload table while transferring a plate from the table to a plate processor. If a plate remains on the unload table longer than this timeout and a subsequent plate is waiting to be unloaded from the drum, then the recorder will suspend with an error message. Selecting RESUME at this point will re-start the timer.


    Type:

    uint16

    Default:

    • 30

    Range:

    • 0 to 600 [seconds]

    Notes:


    Partition:

    cfg

    See Also:

  • NVS: al pes

  • Go to CTP Firmware NVS Parameter Index Page

    Go to CTP Firmware NVS Parameter Search Page

    Go to CTP Firmware Main Page


    Creo CTP F/W NVS Parameter Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:03:26 2002 PST