NVS Parameter: state bay pend


Long Name:

images_pending

Applies to:

  • Platesetter_3244
  • Platesetter_VLF

  • Description:

    This state parameter is not normally modified with the 'set' command. The firmware uses this parameter for internal 'housekeeping'.

    This parameter indicates how many image commands are waiting to pick plates from this bay. This parameter is automatically set to zero at startup and then whenever there are no picks pending on any bay. There have been firmware bugs which did not clear this parameter properly, resulting in an "Images pending on bay, can't load" error when no images were queued. The recorder had to be reset or this parameter had to be cleared manually. These bugs should now be fixed.


    Type:

    integer

    Default:

    • 0

    Range:

    • 0 to 255

    Notes:


    Partition:

    state

    See Also:


    Go to CTP Firmware NVS Parameter Index Page

    Go to CTP Firmware NVS Parameter Search Page

    Go to CTP Firmware Main Page


    Creo CTP F/W NVS Parameter Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:03:28 2002 PST