Long Name: | machtype |
Applies to: |
|
Description: |
For the 3230/3244 Trendsetter 'b' (starting at V2.31), the 3230/3244 Trendsetter Autoloader (starting at V1.30), 3230/3244 Trendsetter Spectrum (starting at V1.40) and Proofsetter (starting at V1.40), this parameter holds the machine type. Base Trendsetter:
Trendsetter Autoloader as of V1.42:
Trendsetter Autoloader prior to V1.42:
Trendsetter Spectrum:
Proofsetter:
This parameter can only be set using the "config" command during the first two minutes after startup. Configuring a machine as an E-type (entry-level) machine disables several features such as temperature compensation and geometric correction. The S, F, or V speed determines the throughput of the machine. For the Trendsetter Autoloader, this parameter also determines whether to use the solenoid mapping for TS3 or for TS4 and TS8. For Platesetters, this parameter was used for development purposes only. The dongle is a security device that is connected to a serial port on the back of the MPE backplane. The dongle is programmed during integration and cannot be changed in the field. The dongle's contents are read by the MPE firmware when the machine is running. |
Type: | string |
Default: |
|
Range: |
|
Notes: |
Currently, only the VLF Platesetter uses the dongle. There are no plans to support the dongle on the Green 3244 Platesetters in the future. |
Partition: | cfg |
See Also: |
|
Go to CTP Firmware NVS Parameter Index Page