NVS Parameter: dpe pbw


Long Name:

mode1_spot_width

Applies to:

  • Green

  • Description:

    Width of the spot, in pixels, when calibrating or measuring the stroke in mode 1. Normally, this parameter is not changed from the default value. The spot width in pixels for other modes is calculated to make it's physical size as close to the mode 1 spot size as possible. For example, if mode 1 is 2400 DPI and this parameter is 3, the spot width in pixels for 1600 and 3200 DPI will be 2 and 4.


    Type:

    integer

    Default:

    • 3

    Range:

    • 1 to 50 [pixels]

    Notes:


    Partition:

    cfg

    See Also:

  • NVS: dpe pbi

  • Go to CTP Firmware NVS Parameter Index Page