NVS Parameter: gc mssa


Long Name:

mscan_shift_adjust

Applies to:

  • All

  • Description:

    Adjusts the image position in the mainscan (around drum) direction. This parameter is calibrated during factory integration and normally should not change after this. Adjustments should be made either with advice from factory integrators or with the special plate registration measuring jig.

    Make this parameter larger (more positive) to shift the image away from the leading edge.


    Type:

    real

    Default:

    • 0

    Range:

    • -5000.0 to 5000.0 [mils]

    Notes:


    Partition:

    cal

    See Also:

  • NVS: gc mss
  • NVS: mode mssa

  • Go to CTP Firmware NVS Parameter Index Page

    Go to CTP Firmware NVS Parameter Search Page

    Go to CTP Firmware Main Page