NVS Parameter: hdp brt


Long Name:

beam_balance_ready

Applies to:

  • Thermal

  • Description:

    The "beam balance ready" time specifies the time to wait after turning the laser on and before measuring the beam with the beam balance sensor.

    Having this value too low (ie. less than 20 seconds) will cause the stroke profile of the beam to be measured incorrectly. Enough time is required to allow the sensor to stabilize before any measurements are taken. The recommended value is now 40 seconds.


    Type:

    integer

    Default:

    • 20

    Range:

    • 0 to 1800 [seconds]

    Notes:


    Partition:

    cfg

    See Also:


    Go to CTP Firmware NVS Parameter Index Page

    Go to CTP Firmware NVS Parameter Search Page

    Go to CTP Firmware Main Page