NVS Parameter: head humidity


Long Name:

humidity

Applies to:

  • Thermal

  • Description:

    The thermal head firmware monitors the humidity using a sensor mounted within the thermal head. If the humidity exceeds the configured threshold, then the thermal head is shutdown. Any plot in progress is aborted.

    If this parameter is set to zero, then the humidity sensor is ignored by the thermal head firmware. This value should never be set to zero on any head in the field since water condensation on the laser will cause laser failure.


    Type:

    real

    Default:

    • 30.000

    Range:

    • 0.000 to 60.000 [%]

    Notes:

    Applies to Thermal Head firmware version 1.30 and above


    Partition:

    cal

    See Also:


    Go to CTP Firmware NVS Parameter Index Page

    Go to CTP Firmware NVS Parameter Search Page

    Go to CTP Firmware Main Page


    Creo CTP F/W NVS Parameter Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:03:38 2002 PST