NVS Parameter: head fthresh


Long Name:

focus_error_thresh

Applies to:

  • Thermal

  • Description:

    Specifies the focus error threshold. Focus error measurements larger than this for a duration set by the ferrdur value indicate that the media is out of focus and generate a workstation warning message at the end of the plot. Setting fthresh to 0 disables checking for focus error out of range.

    This parameter should never be 0 for any head in the field.


    Type:

    integer

    Default:

    • 150

    Range:

    • 0 to 32767

    Notes:


    Partition:

    cfg

    See Also:

  • NVS: head ferrdur
  • Error: E_HEAD_FOCUS_OUT_OF_RANGE

  • Go to CTP Firmware NVS Parameter Index Page

    Go to CTP Firmware NVS Parameter Search Page

    Go to CTP Firmware Main Page


    Creo CTP F/W NVS Parameter Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:03:41 2002 PST