NVS Parameter: head scands


Long Name:

scan_drum_speed

Applies to:

  • Thermal

  • Description:

    The drum speed to use during the scanning part of the automatic banding correction. Used only in conjunction with the plate scan automatic banding correction. There should never be any need to adjust this parameter. The setting will not affect imaging.


    Type:

    real

    Default:

    • 10.000

    Range:

    • 0.000 to 200.000 [rpm]

    Notes:


    Partition:

    cfg

    See Also:

  • Command: plot phase
  • Command: plot flatten

  • Go to CTP Firmware NVS Parameter Index Page

    Go to CTP Firmware NVS Parameter Search Page

    Go to CTP Firmware Main Page


    Creo CTP F/W NVS Parameter Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:03:42 2002 PST