NVS Parameter: laser st


Long Name:

standby_timeout

Applies to:

  • Green

  • Description:

    Number of consecutive minutes of idle time (no images active) until the laser is switched into "standby" mode. Normally, this parameter is not changed from the default value. Standby mode is disabled if this parameter is 0. The type of standby mode is set with the laser sm parameter.


    Type:

    integer

    Default:

    • 60

    Range:

    • 0 to 254 [minutes]

    Notes:

    This parameter may need to be adjusted to suit the work patterns of a particular installation. For example, if a normal idle time is longer than 60 minutes, the standby_timeout could be lengthed to avoid a regular warmup period.


    Partition:

    cfg

    See Also:

  • NVS: laser sm
  • NVS: laser wthr
  • NVS: laser cthr

  • Go to CTP Firmware NVS Parameter Index Page