NVS Parameter: media cthk


Long Name:

carrier_thickness

Applies to:

  • Thermal
  • ThermoFlex

  • Description:

    For some plates, ie. proofs or Kodak DITF we now require a carrier below the plate. This addition of a carrier will throw off the scaling calculations for the machine (when imaging with the carrier) since the machines are GC'ed with plain aluminum plates. If a carrier is to be used with the selected media then this parameter needs to be set to the corresponding thickness of the carrier. Once this is done the device will then produce plates with correctly sized images. Please note that this scaling error will only show up in the main scan direction.


    Type:

    integer

    Default:

    • 0

    Range:

    • 0 to 6500 [microns]

    Notes:


    Partition:

    cal

    See Also:

  • NVS: gc ssca

  • Go to CTP Firmware NVS Parameter Index Page

    Go to CTP Firmware NVS Parameter Search Page

    Go to CTP Firmware Main Page


    Creo CTP F/W NVS Parameter Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:03:44 2002 PST