NVS Parameter: media ltol


Long Name:

tolerance_limit

Applies to:

  • Green

  • Description:

    Absolute maximum deviation from the target exposure allowable in a calibrated stroke. The tolerance will be increased from "media stol" until this tolerance limit is exceeded. Normally, this parameter is not changed from the default value. Making this parameter too small may lead to the firmware reporting the "Can't flatten stroke" error message. Making this parameter too large may lead to imaging artifacts from non-flat strokes.


    Type:

    real

    Default:

    • 1

    Range:

    • 0.0 to 32.0 [%]

    Notes:


    Partition:

    cal

    See Also:

  • NVS: media stol

  • Go to CTP Firmware NVS Parameter Index Page

    Go to CTP Firmware NVS Parameter Search Page

    Go to CTP Firmware Main Page


    Creo CTP F/W NVS Parameter Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:03:45 2002 PST