NVS Parameter: media pcfg


Long Name:

punch_config

Applies to:

  • Trendsetter_400/800_Auto

  • Description:

    The AutoPunch is an automatic punching unit built by Ternes Register System that sits between the Trendsetter AL unload table and the processor line.

    The punch_config parameter specifies the punch configuration value associated with the media type. Making the punch configuration a media parameter allows the operator to change the punch configuration from the workstation.

    Ternes will have configured the punch for different plate sizes, and will have defined a number between 1 and 19 for each configuration. This configuration number should be put into the punch_config parameter.

    A different media type must be setup for each different punch configuration. The command "punch media <src> <dest>" has been added to facilitate the task of copying media and hdm parameters from one media type to another.

    This parameter should be set to 0 for media types that are not to be punched.


    Type:

    byte

    Default:

    • 0 (disabled)

    Range:

    • 0 to 19

    Notes:

    This parameter is only available on MPE V1.30 and above.

    Punching requires both the punch and the rotator to be installed ("al ri" and "al pi" set to 1).


    Partition:

    cal

    See Also:

  • NVS: al pi
  • NVS: al ri
  • Command: punch

  • Go to CTP Firmware NVS Parameter Index Page

    Go to CTP Firmware NVS Parameter Search Page

    Go to CTP Firmware Main Page