NVS Parameter: media sens


Long Name:

default_sensitivity

Applies to:

  • All

  • Description:

    Sensitivity used if no plate has been auto-loaded onto the drum. For example, this sensitivity will be used if the load/unload script files are used or if "set sys load" is 0 and no plate is on the drum. A sensitivity of 0 will cause stroke calibration to be bypassed.


    Type:

    real

    Default:

    • 170

    Range:

    • 0.0 to 500.0 [uJ/cm^2]

    Notes:

    This parameter was moved to the hdm subsystem for Thermal builds using thermal module 2.58 or greater, and was renamed nominal_sensitivity.


    Partition:

    cal

    See Also:

  • NVS: hdm sens

  • Go to CTP Firmware NVS Parameter Index Page

    Go to CTP Firmware NVS Parameter Search Page

    Go to CTP Firmware Main Page


    Creo CTP F/W NVS Parameter Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:03:45 2002 PST