NVS Parameter: media thk


Long Name:

default_thickness

Applies to:

  • All

  • Description:

    Plate thickness used while imaging when no plate has been auto-loaded onto the drum. For example, this thickness will be used if the load/unload script files are used or if "set sys load" is 0 and no plate is on the drum. The plate thickness is needed by the HRX head to focus the writing spot on the plate. This thickness can be safely set to 0.


    Type:

    integer

    Default:

    • 305

    Range:

    • 0 to 1000 [microns]

    Notes:


    Partition:

    cal

    See Also:

  • NVS: sys load

  • Go to CTP Firmware NVS Parameter Index Page

    Go to CTP Firmware NVS Parameter Search Page

    Go to CTP Firmware Main Page


    Creo CTP F/W NVS Parameter Documentation / ctp_firmware@creo.com / Updated: Tue May 14 20:03:46 2002 PST