NVS Parameter: mode dpi


Long Name:

rip_dpi

Applies to:

  • All

  • Description:

    Defines the dpi of the RIP data for this mode. If this parameter is 0, the mode is considered undefined. Note that the RIP dpi (or input dpi) will be different than the output dpi if either mode msd (mscan_duplicate) or mode ssd (sscan_duplicate) is greater than 1.


    Type:

    integer

    Default:

    • 2400
    • 1200 (Trendsetter_NEWS)

    Range:

    • 0 to 3200

    Notes:


    Partition:

    cfg

    See Also:

  • NVS: mode msd
  • NVS: mode ssd
  • NVS: hdp dpi

  • Go to CTP Firmware NVS Parameter Index Page

    Go to CTP Firmware NVS Parameter Search Page

    Go to CTP Firmware Main Page